EQ format and EasyEffects interchange ​

This page covers how a channel's EQ is stored, how its filters are calculated, and how it converts to and from EasyEffects presets. The filter maths is in rc2fx-core, and both the app's curve display and the mixer's processing use it, so they produce the same coefficients.

Stored form ​

json
{
  "enabled": true,
  "inputGainDb": 0,
  "outputGainDb": 0,
  "bands": [
    {
      "id": "band-1",
      "enabled": true,
      "type": "bell",
      "mode": "apo-dr",
      "solo": false,
      "frequency": 1000,
      "gain": 0,
      "q": 1
    }
  ]
}
FieldValues
bands0–32 bands
idLowercase letters, digits and hyphens, up to 48 characters, unique within the channel
typeoff, bell, low-shelf, high-shelf, low-pass, high-pass, notch
modeapo-dr (Equalizer APO's model) or rlc-bt
frequency10–24000 Hz
gain−36 to +36 dB
q0–100
inputGainDb, outputGainDb−36 to +36 dB, applied inside the EQ
  • Band IDs are stable. Reordering or deleting bands leaves the other bands' IDs unchanged, which lets the mixer keep each band's filter state across an edit.
  • An optional rightBands array gives the right channel of a stereo target its own bands. Without it, both channels use bands. An empty rightBands array means the right channel is independent and has no bands.
  • If any band has solo: true, only soloed bands process audio. Disabled bands and off bands do not process audio.
  • A disabled EQ bypasses its bands and both gains. An enabled EQ with no bands still applies its gains.
  • New channels start with no bands and the EQ off. A new band is an enabled bell in APO mode at 1 kHz, Q 1, 0 dB.

Every value must be finite and of the correct type. Unknown fields, duplicate keys or IDs, and out-of-range values are rejected. Invalid values are not corrected.

Filter maths ​

The sample rate is 48 kHz. The frequency is stored as entered, and the filter is designed at min(frequency, 0.49 × 48000).

apo-dr uses the standard RBJ cookbook formulas with Q = max(storedQ, 0.1).

rlc-bt converts its Q and then uses the same formulas. For a bell, with g = 10^(gain/20):

text
Q_RBJ = (1 + 2·storedQ) · √g / (2·√(1 + g²))

For the other types, Q_RBJ = (1 + storedQ) / 2.

Shelves compute alpha from Q. They do not use the shelf slope S. Pass and notch filters store a gain but do not apply it. The stored mode and Q are always the originals, so a gain change recomputes the converted Q correctly. Reference formulas and independent coefficient vectors are in fixtures/easyeffects/.

Adding, removing or reordering bands does not restart the other effects or noise suppression. Bands that remain after an edit keep their filter state.

EasyEffects presets ​

Import and export are a separate pure module in rc2fx-core. An import changes only the selected channel's EQ.

Export ​

Export writes an EasyEffects pipeline preset that contains only the equalizer:

  • The pipeline is input for microphones and output for all other targets.
  • It contains equalizer#0 with both channels and an explicit value for every band field RC2FX has.
  • slope and width are omitted, so EasyEffects uses its defaults (x1 and 4 octaves).
  • A disabled band is written as mute: true.
  • An empty EQ is written as one neutral off band.
  • If one independent channel has fewer bands, it is padded with off bands.
  • At most 32 bands are written.

Import ​

Import accepts current Qt and GTK-style presets and the older unindexed equalizer key. Omitted fields take EasyEffects' defaults. A preset with other effects is accepted, and only its equalizer is read.

  • If a file contains more than one equalizer or pipeline, the app asks which one to use.
  • Different left and right bands become independent bands on a stereo target. On a mono target the app asks whether to use the left or right channel.
  • slope and width are read and ignored. RC2FX processes each band as a single filter section and has no width parameter, so a band with a slope above x1 sounds gentler than in EasyEffects. This is the only setting RC2FX approximates.
  • Other settings RC2FX cannot reproduce exactly cause the import to be refused with a short reason: unsupported processing modes or filter types, "decramp", non-zero balance or pitch, and malformed or out-of-range values. A refused import leaves the current EQ unchanged.

The same module reads Equalizer APO and AutoEQ parametric text.

Presets are treated as data. The importer does not execute or download anything from them.